The Effect of Fire to the Compressive Strength of Concrete Containing Recycle Plastic Aggregate (RPA)

机译:火灾对含有回收塑料聚集体(RPA)的混凝土抗压强度的影响

获取原文

摘要

The Polyethylene terephthalate (PET) waste flake was used in concrete with partial replacement of 15%, 25% and 35% by volume of conventional fine aggregate. Four batches of concrete specimens including one without plastic aggregate, for comparison purpose, were prepared. All the concrete specimens were tested for its different mechanical properties after a curing period of 7, 14 and 28 days. Various physical properties of fresh concrete properties were also tested in the laboratory. It was found that the compressive strength of concrete specimen reduces as the waste PET increases. In conclusion, 15% plastic aggregate in concrete is found to be the most suitable replacement proportion. Furthermore, it is concluded that the use of waste PET in concrete provides some advantages such as reduction in the use of conventional aggregate, disposal of wastes, prevention of environmental pollution, and energy saving.
机译:聚对苯二甲酸乙二醇酯(PET)废薄片用于混凝土,部分替代为15%,25%和35%体积的常规细骨料。制备了四批包括一个没有塑料聚集体的混凝土样本,用于比较目的。在7,14和28天的固化期后,测试所有混凝土样本的不同机械性能。在实验室还测试了新鲜混凝土性质的各种物理性质。发现混凝土试样的抗压强度随着废物宠物的增加而减少。总之,混凝土中的15%塑料骨料被发现是最合适的更换比例。此外,得出结论是,使用废物宠物在混凝土中的使用提供了一些优点,例如使用常规总,处理废物,防止环境污染和节能等优点。