首页> 外文会议>International Conference on Manufacturing Technologies >Real-time Visualization of Lubricant Films on Head Slider Using an Ellipsometric Microscope
【24h】

Real-time Visualization of Lubricant Films on Head Slider Using an Ellipsometric Microscope

机译:使用椭圆显微镜的头滑块上润滑膜的实时可视化

获取原文

摘要

As the recording density increased in hard disk drives (HDDs), the head disk interface (HDI) spacing has been decreased to 2-3 nm during its operation. The head slider may pick up the lubricant at this contact or near-contact HDI. Therefore, a real-time visualization of lubricant thickness distribution on a slider surface is essential to study the physical mechanisms for reducing the head disk interface spacing. A vertical-objective-based ellipsometric' microscope (VEM) was presented as the effective method for real-time visualization of nm-thick lubricant films on disks with high lateral resolution. However, extinction coefficient of head slider is low, which means the intensity of reflected light may be reduced. In this report, the feasibility of VEM used for head observation is discussed, and the images of polar perfluoropolyether (PFPE) lubricant Zdol4000 applied on head slider are obtained by the current setup. It indicates that this method can be used in real-time visualization of nm-thick lubricant films on head slider.
机译:随着在硬盘驱动器(HDDS)中的记录密度增加,头部磁盘接口(HDI)间距在其操作期间已经降低到2-3nm。头部滑块可以在该接触或接近的HDI上拾取润滑剂。因此,滑块表面上的润滑剂厚度分布的实时可视化对于研究用于减少头部盘界面间距的物理机制是必要的。基于垂直目标的椭圆形状的显微镜(VEM)作为具有高横向分辨率的磁盘上的NM厚润滑膜的实时可视化的有效方法。然而,头滑块的消光系数低,这意味着可以减少反射光的强度。在本报告中,讨论了用于头部观察的VEM的可行性,并且通过电流设置获得施加在头滑块上的极性全氟聚醚(PFPE)润滑剂Zdol4000的图像。表示该方法可用于头滑块上Nm厚润滑膜的实时可视化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号