首页> 外文会议>International Conference on Medical and Biological Engineering >Adaptive Filter Removes Variability Caused by Respiration from Impedance Cardiography Signal
【24h】

Adaptive Filter Removes Variability Caused by Respiration from Impedance Cardiography Signal

机译:自适应过滤器去除受阻呼吸引起的可变性阻抗心脏造影信号

获取原文

摘要

Impedance cardiography (ICG) allows to measure parameters of heart mechanical function. ICG is sensitivity to movement artifacts inter alia breathing, which distorts impedance signal. Several methods were proposed to eliminate this distortion, but they cannot be used to continuous measurement or do not remove movement artifact. Adaptive filter is event-related, it learns signal characteristic within the cycle and removes components uncorrelated with the event. In this study, we compared ICG signal obtained during normal breathing with that after adaptive filtration and ICG signal obtained during momentary breath holding with this signal processed with adaptive filter. We conclude that adaptive filtering may help extract information from noisy and distorted ICG signal, but on the other hand, it may obscure some real changes in signal, for instance, rapid cyclic changes connected with respiration.
机译:阻抗心脏造影(ICG)允许测量心脏机械功能的参数。 ICG尤其是呼吸的运动伪影敏感性,这使阻抗信号扭曲。提出了几种方法来消除这种失真,但它们不能用于连续测量或不移除运动伪影。自适应过滤器是事件相关的,它可以在循环中学习信号特性,并删除与事件不相关的组件。在这项研究中,我们将在正常呼吸期间获得的ICG信号与在用自适应滤波器处理的该信号的瞬时呼吸保持期间获得的自适应过滤和ICG信号。我们得出结论,自适应滤波可能有助于从嘈杂和失真的ICG信号中提取信息,但另一方面,它可能会掩盖信号中的一些实际变化,例如,与呼吸相关的快速循环变化。