首页> 外文会议>SPIE Conference on Laser Florence: Advances in Laser Medicine >Low-level laser therapy equipment needs calibration before clinical use
【24h】

Low-level laser therapy equipment needs calibration before clinical use

机译:低级激光治疗设备在临床使用前需要校准

获取原文

摘要

Background: Many factors can influence the radiant power delivered by the low-level laser therapy (LLLT) equipment, such as its cleaning and condition, as well as the use of plastic films for protecting the laser or even its time of use. Radiant power is an important factor to consider because it affects the amount of energy delivered to the target tissue. The difference between real radiant power (RRP) and nominal radiant power (NRP) may interfere in the expected results, because the delivered energy is different from the desired energy. Purpose: The objective of this study was to compare the NRP with the RRP offered by LLLT devices under clinical conditions of use. Material and Methods: For data collection to this study, 61 LLLT devices used in private and public dental practices in the state of Tocantins, Brazil, were evaluated. Three consecutive power measurements were performed at one-minute intervals and then the average of the measured power was calculated. The RRP was compared to the NRP. Results: The equipment presented NRP from 30 to 500mW while RRP ranged from 17.3 to 107.OmW. Discussion and Conclusion: The mean power measured in clinical conditions of use of the laser equipment was different from the nominal power reported by the manufacturers of the devices (p<0,01). The RRP ranged between 12.92% and 107% of NRP. This fact is worrisome, since one of the most important parameters for the success of the treatment of an injury using LLLT is the energy (power x time) delivered. These findings reinforce the need of calibrating the equipment before each laser application in order to avoid failures in the therapeutic conduct.
机译:背景:许多因素可以影响低水平激光治疗(LLLT)设备(例如其清洁和条件)提供的辐射功率,以及使用塑料薄膜来保护激光甚至其使用时间。辐射功率是需要考虑的重要因素,因为它会影响输送到靶组织的能量。真实辐射功率(RRP)和标称辐射功率(NRP)之间的差异可能干扰预期的结果,因为传递的能量与所需能量不同。目的:本研究的目的是将NRP与LLLT设备提供的RRP进行比较,在临床使用条件下。材料和方法:对于本研究的数据收集,评估了巴西托卡林纳州私人和公共牙科实践的61个LLLT设备。三个连续功率测量以一分钟的间隔进行,然后计算测量功率的平均值。将RRP与NRP进行比较。结果:该设备从30到500MW呈现NRP,而RRP则从17.3到107.MW。讨论和结论:激光设备使用临床用途中测量的平均功率与器件制造商报告的标称功率不同(P <0.01)。 RRP的范围为12.92%和107%的NRP。这一事实是令人担忧的,因为使用LLLT治疗伤害的成功的最重要参数之一是所提供的能量(电源X时间)。这些发现强化了在每个激光应用前校准设备的需要,以避免治疗行为中的故障。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号