首页> 外文会议>Conference on Lasers in dentistry XXIII >Investigations on the potential of a novel diode pumped Er:YAG laser system at high mean laser power for hard tissue preparation in dentistry
【24h】

Investigations on the potential of a novel diode pumped Er:YAG laser system at high mean laser power for hard tissue preparation in dentistry

机译:新型二极管泵浦ER潜力的研究:在高平均激光动力下的晶体激光系统在牙科硬组织制备

获取原文

摘要

Several studies have shown the potential of the diode pumped Er: YAG laser for medical applications. Benefits are the efficient and precise ablation of both hard and soft tissue with adjustable thermal effects. Aim of this study is the investigation of the ablation process on dentin and enamel using the diode pumped Er:YAG laser even at higher mean laser power and two different handpieces (free beam vs. contact). At first the laser radiation of the diode pumped Er:YAG laser (DPM-25, PANTEC Engineering AG) was coupled into a standard dental fiber delivery system (KEY3 laser, KaVo GmbH) with the two handpieces for cavity preparation. An appropriate experimental setup was realized including a computer controlled translation stage with sample holder to move the dentin or enamel slides of extracted human teeth with a defined velocity while irradiation by various laser parameters. After irradiation, the cut kerfs were analyzed by light microscopy and laser scanning microscopy. The results show a good ablation quality for both handpieces and a higher ablation rate in dentin and enamel using the non-contact handpiece compared to the contact handpiece. The calculated ablation efficiency is remarkable high (dentin: 0.094 - 0.172 mm~3/J, enamel: 0.025 - 0.093 mm~3/J) and exceeds all published values. The results of the high-speed camera observations explain the differences between the handpieces. In conclusion these experiments with the diode pumped Er:YAG laser system demonstrate its ability for efficient and very fast cavity preparation.
机译:一些研究表明,二极管的潜在抽二:YAG激光医学应用。好处是具有可调节的热效应硬和软组织的高效精确的烧蚀。这项研究的目的是在使用了二极管牙本质和牙釉质消融过程的调查泵浦铒:YAG激光器,即使在较高的平均激光功率和两个不同的机头(免费光束对接触)。在第一二极管的激光辐射泵浦铒:YAG激光(DPM-25,PANTEC工程AG)被耦合到一个标准牙纤维递送系统(KEY3激光,卡瓦GmbH)中与两个机头用于窝洞制备。合适的实验装置来实现,包括带有样本保持器的计算机控制的平移台以具有限定的速度移动中提取的人类牙齿的牙质或牙釉质滑动,同时通过各种激光参数照射。照射后,切割切口通过光学显微镜和激光扫描显微镜分析。结果表明,两个机头良好的消融质量和牙本质更高的消融速率和珐琅使用非接触式手机相比,手机联系。所计算出的消融效率是显着的高(牙本质:0.094 - 0.172毫米〜3 / J,搪瓷:0.025 - 0.093毫米〜3 / J)和超过了所有公布的数值。高速照相机观测的结果解释了手持件之间的差异。总之,这些实验与二极管泵浦铒:YAG激光系统展示其高效率和非常快的腔的准备能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号