首页> 外文会议>Lasers in dentistry XXIII >Investigations on the potential of a novel diode pumped Er:YAG laser system at high mean laser power for hard tissue preparation in dentistry
【24h】

Investigations on the potential of a novel diode pumped Er:YAG laser system at high mean laser power for hard tissue preparation in dentistry

机译:新型二极管泵浦Er:YAG激光系统在高平均激光功率下在牙科硬组织制备中的潜力研究

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Several studies have shown the potential of the diode pumped Er: YAG laser for medical applications. Benefits are the efficient and precise ablation of both hard and soft tissue with adjustable thermal effects. Aim of this study is the investigation of the ablation process on dentin and enamel using the diode pumped Er:YAG laser even at higher mean laser power and two different handpieces (free beam vs. contact). At first the laser radiation of the diode pumped Er:YAG laser (DPM-25, PANTEC Engineering AG) was coupled into a standard dental fiber delivery system (KEY3 laser, KaVo GmbH) with the two handpieces for cavity preparation. An appropriate experimental setup was realized including a computer controlled translation stage with sample holder to move the dentin or enamel slides of extracted human teeth with a defined velocity while irradiation by various laser parameters. After irradiation, the cut kerfs were analyzed by light microscopy and laser scanning microscopy. The results show a good ablation quality for both handpieces and a higher ablation rate in dentin and enamel using the non-contact handpiece compared to the contact handpiece. The calculated ablation efficiency is remarkable high (dentin: 0.094 - 0.172 mm~3/J, enamel: 0.025 - 0.093 mm~3/J) and exceeds all published values. The results of the high-speed camera observations explain the differences between the handpieces. In conclusion these experiments with the diode pumped Er:YAG laser system demonstrate its ability for efficient and very fast cavity preparation.
机译:多项研究表明,二极管泵浦的Er:YAG激光器在医疗领域的潜力。好处是可对硬组织和软组织进行有效而精确的消融,并具有可调节的热效应。这项研究的目的是研究使用二极管泵浦的Er:YAG激光器对牙本质和牙釉质的烧蚀过程,即使在更高的平均激光功率和两个不同的机头(自由光束与接触)的情况下。首先,将二极管泵浦的Er:YAG激光(DPM-25,PANTEC Engineering AG)的激光辐射耦合到带有两个用于准备腔体的牙科手机的标准牙科纤维传输系统(KEY3激光,KaVo GmbH)中。实现了适当的实验设置,包括带有样品架的计算机控制平移台,以在通过各种激光参数照射的同时以定义的速度移动提取的人牙齿的牙本质或牙釉质玻片。照射后,通过光学显微镜和激光扫描显微镜对切下的切口进行分析。结果表明,与接触式手机相比,使用非接触式手机时,两个手机均具有良好的烧蚀质量,并且牙本质和牙釉质的烧蚀率更高。计算出的消融效率非常高(牙本质:0.094-0.172 mm〜3 / J,牙釉质:0.025-0.093 mm〜3 / J),超过了所有公布的值。高速相机观察的结果解释了手机之间的差异。总之,这些用二极管泵浦的Er:YAG激光系统进行的实验证明了其有效且快速地制备腔体的能力。

著录项

  • 来源
    《Lasers in dentistry XXIII》|2017年|100440b.1-100440b.8|共8页
  • 会议地点 San Francisco(US)
  • 作者单位

    Institut fuer Lasertechnologien in der Medizin und Meßtechnik an der Universitat Ulm, Helmholtzstraße 12, 89081 Ulm, Germany;

    Institut fuer Lasertechnologien in der Medizin und Meßtechnik an der Universitat Ulm, Helmholtzstraße 12, 89081 Ulm, Germany;

    Institut fuer Lasertechnologien in der Medizin und Meßtechnik an der Universitat Ulm, Helmholtzstraße 12, 89081 Ulm, Germany;

    Institut fuer Lasertechnologien in der Medizin und Meßtechnik an der Universitat Ulm, Helmholtzstraße 12, 89081 Ulm, Germany;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Er:YAG laser; diode-pumped; high repetition rate; 2.94 μm; dental hard tissue; ablation;

    机译::: YAG激光;二极管泵浦重复率高; 2.94微米牙齿硬组织烧蚀;