The sleeve cable force sensor based on magnetoelastic effect has developed rapidly in recent years,and has been widely used in the field of bridge cable force measurement in China.Existing sleeve cable force sensor needs to be installed at the beginning of construction,so it is difficult to reinstall them later,and its long-term performance is also difficult to evaluate and measure online.To solve this problem,the tension measurement of the designed by-pass excitation cable force sensor is carried out,and the influence of signal line length and ambient temperature on the measurement results is analyzed.The results show that the designed by-pass excitation cable force sensor has high linearity,which is expected to solve the problem of the existing sleeve cable force sensor.
机译:近年来,基于磁力弹性效应的套筒电缆力传感器迅速发展,已广泛应用于中国桥梁电缆力测量领域。需要在施工开始时安装套筒电缆力传感器,所以它是 难以在以后重新安装它们,并且其长期性能也难以在线评估和测量。解决这个问题,进行了设计的旁路激励电缆力传感器的张力测量,信号线长度的影响 分析了测量结果的环境温度。结果表明,设计的旁通激励电力传感器具有高线性,预计将解决现有套筒电缆力传感器的问题。