首页> 外文会议>SPIE Conference on Biophotonics >Investigation of temperature feedback signal parameters during neoplasms treatment by diode laser radiation
【24h】

Investigation of temperature feedback signal parameters during neoplasms treatment by diode laser radiation

机译:二极管激光辐射治疗肿瘤处理期间温度反馈信号参数的研究

获取原文

摘要

Dynamics of temperature signal in operation area and laser power at nevus, papilloma, and keratoma in vivo removal by a 980±10 nm diode laser with "blackened" tip operating in continuous (CW) mode and with temperature feedback (APC) mode are presented. Feedback allows maintaining temperature in the area of laser treatment at a preset level by regulating power of diode laser radiation (automatic power control). Temperature in the area of laser treatment was controlled by measuring the amplitude of thermal radiation, which occurs when tissue is heated by laser radiation. Removal of neoplasm was carried out in CW mode with laser radiation average power of 12.5±0.5 W; mean temperature in the area of laser treatment was 900±10°C for nevus, 800±15°C for papilloma, and 850±20°C for keratoma. The same laser radiation maximal power (12.5 W) and targeted temperature (900°C) were set for nevus removal in APC mode. The results of investigation are real time oscillograms of the laser power and temperature in the area of laser treatment at neoplasms removal in two described above modes. Simultaneously with the measurement of laser power and the temperature in the area of laser treatment video recording of surgeon manipulations was carried out. We discuss the correlation between the power of the laser radiation, the temperature in the area of laser treatment and consistency of surgeon manipulation. It is shown that the method of removal (excision with or without traction, scanning) influences the temperature in the area of laser treatment. It was found, that at removal of nevus with temperature feedback (APC) mode to achieve comparable with CW mode temperature in the area of laser treatment (900±10°C) 20-50% less laser power is required. Consequently, removing these neoplasms in temperature feedback mode can be less traumatic than the removal in CW mode.
机译:呈现了980±10nm二极管激光器的痣,乳头状瘤和角膜瘤的温度信号和激光功率的动力学,并在连续(CW)模式下运行的“黑化”尖端和温度反馈(APC)模式进行了980±10nm二极管激光器。反馈允许通过调节二极管激光辐射(自动功率控制)的功率来保持在预设水平的激光处理区域中的温度。通过测量热辐射的幅度来控制激光处理区域的温度,当通过激光辐射加热组织时发生。在CW模式下进行肿瘤的去除,激光辐射平均功率为12.5±0.5W;激光治疗面积的平均温度为痣为900±10°C,乳头瘤800±15°C,850±20°C用于角癌瘤。将相同的激光辐射最大功率(12.5 W)和靶向温度(900°C)设定为APC模式中的痣去除。研究结果是在上述两种实施方式中在肿瘤中去除的激光处理区域中的激光功率和温度的实时振动图。同时通过测量激光功率和激光处理区域的温度进行外科医生操纵的视频记录。我们讨论了激光辐射功率之间的相关性,激光处理区域的温度和外科医生操纵的一致性。结果表明,去除的方法(有或没有牵引,扫描)的切除​​方法影响激光处理区域的温度。发现,在去除具有温度反馈(APC)模式的Nevus时,在激光处理区域(900±10°C)中的CW模式温度相当,需要更少的激光功率。因此,在温度反馈模式下除去这些肿瘤可以比CW模式的移除更少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号