This paper presents the retrofitting procedure used on a precast reinforced concrete wall panel (PRCWP) in order to restore its initial load bearing capacity. The specimen used in this experimental test is one from the residential multistoried buildings constructed in Romania from the 1970 onwards. All of the characteristics of the element are from the specific era, only scaled down with a factor of 1:1,2. The element was subjected to in-plane reversed cyclic loading to simulate its seismic behavior and obtain its maximum load bearing capacity. After the test we retrofitted the element using Carbon Fiber Strips Externally Bonded (EBR) and anchored with Carbon Fiber Reinforced Polymers (CFRP) mesh. The porpoise of the paper is to compare the maximum loading bearing capacity of the unstrengthen and strengthen elements in order to compare them and examine the efficiency of this retrofitting procedure.
机译:本文介绍了预制钢筋混凝土墙板(PRCWP)上使用的改装程序,以恢复其初始承载能力。在该实验测试中使用的标本是来自1970年的罗马尼亚建造的住宅多层建筑中的一个。元素的所有特征都来自特定的时代,仅缩小为1:1,2。将该元件进行在线逆转的循环载荷以模拟其地震行为并获得其最大承载能力。测试后,我们使用外部粘合(EBR)的碳纤维条改装元件并用碳纤维增强聚合物(CFRP)网锚固。纸张的PORPOIES是为了比较未强度和加强元件的最大装载能力,以比较它们并检查这种改装程序的效率。