A new system based on solar photovoltaic/thermal-ground source heat pump (PV/T-GSHP) was proposed to solve the problems of energy shortage and high energy-consuming buildings in China. The operation performance of the PV/T-GSHP system in a demonstration project in Dalian of China was studied and energy saving performance was analyzed. The results show that this PV/T-GSHP system can reduce the temperature of photovoltaic/thermal modules as high as 10癈, and improve the efficiency of electricity production by 25%, simultaneously. And in heating season the average COP of the heat pump remains around 3. Then the model of the PV/T-GSHP system was established based on the Polysun software, the system parameters were optimized, followed by analyzing the technical and economic of the project. The optimization data and energy saving effect of this demonstration system can provide guidance for future related project.
机译:提出了一种基于太阳能光伏/热地源热泵(PV / T-GSHP)的新系统,以解决中国能源短缺和高耗能建筑物的问题。研究了中国大连展示项目的PV / T-GSHP系统的运行性能,分析了节能性能。结果表明,该PV / T-GSHP系统可以将光伏/热模块的温度降低至10‰,同时提高电力生产效率25%。在加热季节,热泵的平均COP保持左右3.然后根据PolySun软件建立PV / T-GSHP系统的模型,系统参数进行了优化,然后分析了项目的技术和经济。该演示系统的优化数据和节能效果可以为未来的相关项目提供指导。