In the temperature and humidity independent air conditioning system, the fresh air units, in addition to bear all the new wind load, indoor wet load and part of the indoor cooling load, also need to control the temperature of supply air and prevent condensation. This paper pro-poses a new concept for the construction of fresh air units and found: the heat recovery should be carried out in different ways according to the degree of the exhaust air pollution; the use of water-cooled surface cooler with the combination of direct expansion type can improve the overall energy efficiency of the cooling dehumidification system; the reheat of condensing heat, secondary thermal recovery and the adjustment of supply air temperature can achieve through the use of double condenser and double expansion valve structure.
机译:在温度和湿度无关的空调系统中,新鲜空气装置,除了承载所有新的风力负荷,室内湿负荷和一部分室内冷却负载,还需要控制供气的温度并防止冷凝。本文提出了新的概念,用于建造新鲜空气装置,发现:应根据排气污染程度以不同的方式进行热量回收;使用具有直接膨胀型的组合的水冷表面冷却器可以提高冷却除湿系统的总能效;通过使用双电容和双膨胀阀结构,可以实现冷凝热,二次热回收和供应空气温度调节的再热。