This paper describes a rapid, accurate method for the determination of the content of SO3 in slag powder before and after burning, with reference to the pretreatment method of the relevant national standard. We tested the content of SO3 in slag powder before and after burning by inductively coupled plasma-optical emission spectrometry (ICP-AES), then the result of burning loss was corrected by the content of SO_3. The content of SO3 which was determined by this new method is fast and accurate, compared with the traditional method. We selected the wavelength of 182.0 nm as spectral analysis of SO_3. The detection limit of the method (3S) was 0.016 mg/L. Test for recovery was performed by standard addition method, giving values of recovery in the ranges of 97%-104%. And the relative standard deviation (n=6) of the parallel samples was less than 1.05%.
机译:本文介绍了在燃烧之前和之后测定炉渣粉末中SO 3含量的快速,准确的方法,参考相关国家标准的预处理方法。通过电感耦合等离子体光发射光谱法(ICP-AES)在燃烧之前和之后在炉渣粉末中的SO3中的含量测试,然后通过SO_3的含量校正燃烧损失的结果。与传统方法相比,通过这种新方法确定的SO 3的含量快速准确。我们选择了182.0nm的波长,作为SO_3的光谱分析。方法(3S)的检测限为0.016mg / L.通过标准加法方法进行恢复测试,给出97%-104%的恢复值。并联样品的相对标准偏差(n = 6)小于1.05%。