首页> 外文会议>International Conference on Machinery, Materials and Computing Technology >Experimental study for Infrared Temperature Measurement System
【24h】

Experimental study for Infrared Temperature Measurement System

机译:红外温度测量系统的实验研究

获取原文

摘要

Infrared temperature measurement system is designed, Based on C51 microcontroller and infrared temperature sensor. The experimental study is executed for the character of designed system, and the results show as follows: for the range of 2.5-15cm, the error of measurement error is very small, less than 1°C; but in between 20-27cm, the error increased gradually. Overall the infrared thermometer ace achieve stable measurement with high precision and can be widely used in families, hospitals, schools, etc., and has good popularization and application prospect.
机译:基于C51微控制器和红外温度传感器设计红外线测量系统。为设计系统的特征执行了实验研究,结果表明如下:对于2.5-15cm的范围,测量误差非常小,小于1°C;但在20-27厘米之间,误差逐渐增加。总体而言,红外温度计ACE通过高精度达到稳定的测量,可广泛用于家庭,医院,学校等,并具有良好的普及和应用前景。