Performances of Heat Transfer and Fluid Flow in the Shell and Tube Heat Exchanger with Novel Sextant Fan Baffles

机译:具有新型塞克兰风扇挡板的壳体热交换器中传热和流体流动的性能

获取原文

摘要

For the high shell side pressure drop of the traditional segmental baffled heat exchanger, a novel sextant fan baffled heat exchanger was put forward in this paper. The 3-dimensional physical model of the novel sextant fan baffled heat exchanger was built, CFD software was used to obtain detailed shell side fluid flow behavior and heat transfer performances, comparison was also made between the new and the traditional segmental baffled heat exchanger. Results show that the pressure drop of the new sextant fan baffled heat exchanger is about 72.3-74.6% greater than that of the traditional segmental baffled heat exchanger under the import velocity of shell side from 2 to 10 m~3/h. When the import velocity is low, the difference of heat transfer coefficient between the two heat exchangers is minor, and the comprehensive performance of the new sextant fan baffled heat exchanger is 33.14-65.25% greater than that of the heat exchanger with traditional segmental baffles under various import velocities.
机译:对于传统的节段挡板热交换器的高壳侧压降,本文提出了一种新型塞克兰风扇挡板热交换器。建立了新型塞克兰风扇挡板热交换器的三维物理模型,使用CFD软件来获得详细的壳体侧流体流动行为和传热性能,还在新的和传统的节段间挡板的热交换器之间进行比较。结果表明,新的塞克兰风扇挡板热交换器的压降大约在2至10m〜3 / h的外壳侧的进口速度下大约72.3-74.6%。当进口速度低时,两种热交换器之间的传热系数差异很小,新的塞克兰风扇挡板热交换器的综合性能比具有传统节段挡板的热交换器大于33.14-65.25%各种进口速度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号