摘要

The performance of the instantaneous air-source heat pump water heaters which is made of the different double pipe heat exchangers respectively was studied, the influence of double-pipe inner wall thickness on the heat transfer area, the water flow velocity, the heat transfer coefficient, and the water system resistance of the double pipe heat exchanger was analyzed, and the influence of double-pipe inner wall thickness on heat pump water heater performance was studied in this paper. The experimental results show that: the energy efficiency of heat pump water heater is improved by the appropriate design of double pipe length, in addition, the heat capacity can be increased, and power consumption can be reduced.
机译:研究了由不同双管热交换器制成的瞬时空气源热泵热泵的性能,对双管内壁厚度对传热面积,水流速度,传热系数的影响分析了双管热交换器的水系统电阻,研究了本文研究了双管内壁厚度对热泵热水器性能的影响。实验结果表明:通过适当的双管长度设计,热泵热水器的能量效率得到改善,另外,可以增加热量,并且可以减少功耗。