Pleated fibreglass media filter cartridges are used throughout the auxiliary systems at nuclear power plants across the 58 reactors of EDF fleet. The main role of these filters is to remove suspended solids from coolant to prevent them accumulating in circuits or in equipments. In the primary circuit, these filters therefore limit the deposition of solids that are active or could become active if allowed to recirculate throughout the primary circuit, avoiding potential consequences such as an increase in dose rates, axial offset anomalies, demineralisers fouling, higher pressure losses in primary loop, and clogging of the primary pumps. Since 2008, a steady increase in the consumption of filters has been noticed, and therefore an increase in the amount of solid waste to treat. Preliminary studies have identified the primary circuit high-flow filters of the 1300/1450 MWe reactors as the main source of this increase. Not only has this stretched of solid waste containers production to the limit, as well as strained site resources and increased risks of operational errors during periods of frequent filter changes; it has also suggested that there is an underlying problem that could pose a serious risk to the primary circuit if untreated. Further studies have been carried out to identify more precisely the impact of possible causes, including increased quality surveillance of the filters, correlation of consumption data with the concentrations of various conditioning products and typical pollutants, and an impact analysis of events such as steam generator replacements or new practices like zinc injection. Work has been done with the filter manufacturer to improve their service lifetime and a simulation tool has been developed in order to understand and optimise filtration. We are also working with sites on creating good practices and avoiding bad ones. These actions should reduce the consumption in the short term while still assuring a high quality of filtration and demineralisation. Longer term solutions have also been considered such as alternative filtration technologies and system modifications if the problem persists or worsens.
机译:褶皱玻璃纤维介质过滤器盒在核电厂的整个辅助系统中使用,核电厂穿过EDF舰队的58个反应器。这些过滤器的主要作用是从冷却剂中除去悬浮固体,以防止它们在电路中累积或设备中的累积。因此,在初级回路中,这些过滤器限制了在整个初级回路中再循环的固体沉积,如果允许在整个初级回路中再循环,避免诸如剂量率的增加,轴向偏移异常,脱矿物污垢,更高的压力损失等潜在后果在初级循环中,以及初级泵的堵塞。自2008年以来,已经注意到过滤器消耗的稳步增加,因此对治疗的固体废物量增加。初步研究已经确定了1300/1450 MWE反应器的主要电路高流量滤波器作为这种增加的主要来源。这不仅将固体废物容器延伸到极限,以及应变的位点资源以及在频繁过滤器变化时期的运行误差风险增加;还建议存在一个潜在的问题,如果未经处理,可能会对主要电路构成严重风险。已经进行了进一步的研究,以确定可能原因的影响,包括滤波器的质量增加,消费数据与各种调理产品的浓度和典型污染物的相关性,以及蒸汽发生器替代品等事件的影响分析或像锌注射等新实践。使用过滤器制造商已经完成了工作,以改善其使用寿命,并开发了模拟工具,以便理解和优化过滤。我们也在建立良好做法和避免坏事的网站。这些行动应在短期内降低消费,同时仍可确保高质量的过滤和脱矿质。如果问题仍然存在或恶化,也考虑了较长的术语解决方案,例如替代过滤技术和系统修改。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号