A study to assess alternative water sources for reducing energy consumption in a medical facility case study, Abu Dhabi

机译:评估替代水源降低医疗设施案例研究中的能耗的替代水源,ABU DHABI

获取原文

摘要

This paper presents the case for water and energy conservation in a desert type climate healthcare environment, which is based on the need for Abu Dhabi to decrease potable water and energy consumption to reduce environmental impact. The work documented in this paper is part of the first author's Professional Doctorate change project in Sustainable Built Environment (D.SBE) at Cardiff Metropolitan University with a medical facility case study in the United Arab Emirates (UAE) in use since 2015. The project is investigating the impact of alternative water sources energy consumption versus public network seawater desalinated potable water for outdoor use. The context is a 364 beds hospital in Abu Dhabi with a 21,600m2 building footprint area surrounded by a 36,310m2 vegetated open space. The hospital includes a treated air cooling condensate water system suitable for use as irrigation water and water feature use. The condensate water has been tested in 2016 and 2017 to verify compliance for reuse. Whilst, the water test results demonstrate suitability for outdoor reuse in a healthcare setting, additional alternative water sources such as fire test pump water (450m3/year) have been tested in March 2017, which shows that a tertiary treatment system is needed for its reuse. It was also found that onsite alternative water sources are less energy intensive for irrigation (0.22kWh/m3) and water feature use (39.09kWh/m3) than offsite produced desalinated potable water (55.68kWh/m3 average). The next steps are to quantify the treated condensate water from the air cooling system for 12 months through the newly installed flow meters at the raw condensate water tanks to confirm the 2013 theoretical model and calculate yearly water energy consumption. To date (March 2017) 26 days of data have been recorded (February to March 2017) which align with the model by data extrapolation. This study will help understand how alternative water sources for outdoor use, impact on building systems energy consumption, greenhouse gas emission, operation and maintenance cost and the environment. This study may be beneficial to local competent authorities for making and adjusting standards for energy and water conservation strategies in healthcare settings.
机译:本文提出了沙漠型气候医疗保健环境中的水和节能案例,这是基于阿布扎比的需求来减少饮用水和能源消耗,以减少环境影响。本文记载的工作是第一个作者在可持续建筑环境(D.Sbe)的专业博士学位改变项目的一部分,在加卡迪瓦大都会大学,自2015年以来,在使用的阿拉伯联合酋长国(阿联酋)的医疗设施案例研究。该项目正在调查替代水源能源消耗的影响与公共网络海水脱盐饮用水进行户外使用。背景包括一个364床位,在阿布扎比,21,600平方米的建筑占地面积,周围环绕着36,310平方米的植被开放空间。该医院包括适用于灌溉用水和水特征的处理过处的空气冷却冷凝水系统。冷凝水在2016年和2017年进行了测试,以验证重用的合规性。虽然,水测试结果表明,在医疗保健环境中表现出户外重用的适合性,在2017年3月测试了额外的替代水源,如消防试验泵水(450m3 /年),这表明其重用需要三级处理系统。还发现现场替代水源较少,灌溉能量密集较小(0.22kWh / m3)和水特征使用(39.09kwh / m3),而不是异滴石脱盐饮用水(55.68kwh / m3平均值)。下一步骤是通过在原始冷凝水箱的新安装流量表中量化来自空气冷却系统的经处理的冷凝水12个月,以确认2013年理论模型并计算每年的水能消耗。迄今为止(2017年3月)已录制26天的数据(2月至2017年3月),通过数据推断与模型对齐。本研究将有助于了解户外使用的替代水源,对建筑系统能耗,温室气体排放,操作和维护成本以及环境的影响。本研究可能有利于本地主管当局在医疗保健环境中制定和调整能源和水资源保护策略标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号