首页> 外文会议>Topical meeting on advances in nuclear fuel managment >CORE FOLLOW AND COLD CRITICAL CALCULATIONS OF OPERATION CYCLES AFTER EXTENDED OUTAGE IN BWRS
【24h】

CORE FOLLOW AND COLD CRITICAL CALCULATIONS OF OPERATION CYCLES AFTER EXTENDED OUTAGE IN BWRS

机译:核心遵循和冷酷的临界计算,在BWR中的扩展中断后的操作周期

获取原文

摘要

Core follow and cold critical calculations of several cycles including cycles after extended outage are performed for Japanese commercial BWRs using CASMO-4/SIMULATE-3. The core follow calculation results and cold eigenvalues in cycle after extended outage are compared to those in cycles after normal outage. Hot eigenvalues and traversing in-core probe (TIP) route mean square (RMS) errors are evaluated in the core follow calculation. The comparison shows that the change of reactivity caused by extended outage is properly evaluated, and that the TIP RMS errors are similar between the cycles after normal outage and extended outage. The cold eigenvalues are also evaluated in the cold critical calculation. The levels of cold eigenvalue in cycle after extended outage are similar to those in cycles after normal outage. These comparison results show that CASMO-4/SIMULATE-3 is applicable to the evaluation in cycle after extended outage.
机译:核心遵循和冷临界临界计算,包括使用Casmo-4 / Simulate-3的日本商业BWR执行长期停电后的循环。将核心遵循计算结果和循环后的冷特征值与正常中断后的循环中的循环中的循环次数。热特征值和穿过核心探针(尖端)路线平均方形(RMS)误差在核心遵循计算中进行评估。比较表明,延长中断引起的反应性的变化被适当地评估,并且尖端RMS误差在正常停电后循环与扩展中断之间相似。还在冷临界计算中评估了寒冷的特征值。长期停用后循环中的冷特征值水平与正常中断后的循环中的循环相似。这些比较结果表明,Casmo-4 / Simulate-3适用于长期停电后的循环评估。