首页> 外文会议>International Conference on Technologies and Materials for Renewable Energy, Environment and Sustainability >Comparison Study of Vector Control of Induction Motor With and Without Saturation and Iron Loss Fed by Three Level Inverter
【24h】

Comparison Study of Vector Control of Induction Motor With and Without Saturation and Iron Loss Fed by Three Level Inverter

机译:用三级逆变器馈送饱和电动机的载体控制对载体控制的比较研究

获取原文

摘要

This paper is addressed to a comparative study of the vector control of a three phase induction motor based on two mathematical models. The first one is the conventional model based on the assumptions that the saturation and the iron losses are neglected; the second model fully accounts for both the fundamental iron loss and main flux saturation with and without compensation. A rotor resistance identifier is developed, so the compensation of its variation is achieved. The induction motor should be fed through a three levels inverter. The simulation results show the performances of the vector control based on the both models.