摘要

In this paper, wet desulfurization system for a certain 600 MW coal-fired power unit was studied. The field tests were conducted on the limestone wet flue gas desulfurization system of a coal-fired unit. The influence of absorber entrance concentration of SO2 at different loads, as well as the absorber slurry pH value under variable numbers of slurry circulating pumps on desulfurization efficiency were tested. The experiment results also drawn that the start and stop effects of circulating pump on the efficiency of desulfurization rate under different load and the relationship of the slurry density and gypsum quality. On the basis of operation cost analysis, overall power consumption of desulfurization system and the emission fee would be reduced. The optimal operation mode of the slurry circulating pump is given, and the pH value and slurry density are determined.
机译:本文研究了某个600 MW燃煤电源单元的湿脱硫系统。现场试验是在燃煤装置的石灰石湿烟气脱硫系统上进行的。 SO2在不同载荷下的吸收率入射浓度的影响以及在脱硫效率的可变数量下的浆料循环泵下的吸收体浆液pH值。实验结果还绘制了循环泵对不同载荷下脱硫率效率的起点和停止效果及浆料密度和石膏质量的关系。在运营成本分析的基础上,将减少脱硫系统的总功耗和排放费。给出浆料循环泵的最佳操作模式,并确定pH值和浆料密度。