首页> 外文会议>International Congress on Polymers in Concrete >Restoration of glass panel – reinforced concrete grillage roof shell of Ensor Gallery in Ostend (B)
【24h】

Restoration of glass panel – reinforced concrete grillage roof shell of Ensor Gallery in Ostend (B)

机译:恢复玻璃面板 - 钢筋混凝土格栅屋顶壳体(B)

获取原文
获取外文期刊封面目录资料

摘要

The roof of the Ensor-gallery at Ostend is a cylindrical vault, constructed as a coarse grillage of reinforced concrete, with embedded reinforced concrete roof panels with prismatic glass tiles. The concrete ribs of the roof shell were heavily damaged by long term exposure to the chloride containing sea air, causing severe reinforcement corrosion. The paper presents the experimental data on the degradation, as well as the alternative approach used in the restoration project to avoid the loss of a major part of the authentic material. The approach is based on a combination of galvanic cathodic protection with embedded and bored in sacrificing anodes, the application of a chloride inhibiting impregnation followed by a realkalising treatment on the preserved parts, concrete repair and reconstruction with a self-compacting, shrinkage compensating, polymer modified repair mortar. Completely denuded steel reinforcement bars were replaced by glass fiber reinforced polyester rods.
机译:Ensor-Gallery的屋顶是奥塞德的屋顶是一个圆柱形拱顶,构造为钢筋混凝土的粗大炉膛,嵌入式钢筋混凝土屋顶板,带有棱镜玻璃砖。通过长期暴露于含有海风的氯化物,屋顶壳的混凝土肋条严重受损,导致严重的增强腐蚀。本文提出了关于降解的实验数据,以及恢复项目中使用的替代方法,以避免丢失正宗材料的主要部分。该方法是基于通过在牺牲阳极中嵌入和钻孔的电流阴极保护的组合,施加氯化物抑制浸渍,然后对保存的部件,混凝土修复和重建,具有自压缩,收缩补偿,聚合物的抗真实性处理改进修复砂浆。完全剥蚀的钢筋棒被玻璃纤维增​​强聚酯棒取代。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号