Measurements of superficial dose distributions in radiation therapy using translucent cryogel dosimeters

机译:半透明冷冻剂剂量计的放射治疗中浅表剂量分布的测量

获取原文

摘要

Superficial dose distributions were measured using radiochromic translucent poly(vinyl alcohol) cryogels. The relationship between dose to the skin surface and dose measured with the bolus (cryogel) was established using a series of oblique irradiations. Gafchromic film was placed under the bolus, and the ratio of bolus-film dose was determined for angle ranging from 0° to 90°. The average ratio over 0-67.5 degrees (0.800 ± 0.064) was used as the single correction factor to convert dose in bolus to dose to the skin surface, and applied to bolus measurements of skin dose from head and neck intensity modulated radiation therapy (IMRT) treatments delivered to a RANDO phantom. The resulting dose distributions were compared to film measurements using gamma analysis with a 3%/3mm tolerance and a 10% threshold. The minimum gamma pass rate was 95.2%. This study is the first report on the use of a poly(vinyl alcohol) cryogels based dosimeter to provide an accurate estimation of superficial dose distributions in megavoltage photon beams.
机译:使用放射褐色半透明聚(乙烯醇)冷冻胶质测量浅表剂量分布。使用一系列倾斜照射建立了剂量与皮肤表面和用推注(Cryogel)测量的剂量之间的关系。将Gafchromic膜放置在推注下,测定胶卷膜剂量的比例为0°至90°的角度。超过0-67.5度(0.800±0.064)的平均比例用作单一的校正因子,以将借调剂量的剂量转化为皮肤表面,并应用于来自头部和颈部强度调制放射治疗的皮肤剂量的推注测量(IMRT )送到Rando Phantom的治疗。将所得剂量分布与使用3%/ 3mm耐受性和10%阈值的γ分析进行比较。最低伽玛通过率为95.2%。该研究是关于使用基于聚(乙烯醇)CryoGels的剂量计的第一报告,以便在迈瓜光子束中提供浅表剂量分布的精确估计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号