首页> 外文会议>International Conference on 3D Radiation Dosimetry >Comparison between polymer gel dosimetry and calculated dose with small field in stereotactic irradiation
【24h】

Comparison between polymer gel dosimetry and calculated dose with small field in stereotactic irradiation

机译:高分子凝胶剂量测定与立体定向辐射中小场的计算剂量的比较

获取原文

摘要

The purpose of this study is to investigate gel dosimetry for a small irradiation field in stereotactic radiotherapy. Treatment plans were generated by the Pinnacle treatment plan system (TPS) for three different circular irradiated fields: 10 mm, 15 mm, and 20 mm. The polymer gels were irradiated to 6 Gy with 10-, 15-, and 20-mm-diameter collimators in 4 MV photon beams for stereotactic irradiation following TPS. Irradiated gels were evaluated with MRI at 1.5 T with R2 images. Firstly, the line profile of the irradiated center between TPS plan and the R2 image was compared. In the center profile at a dose calculated from the treatment plan, the full width at half maximum (FWHM) of 10-mm, 15-mm, and 20-mm collimators, were 13 mm, 19 mm, and 25 mm, respectively. In the center profile at R2 from the gel dosimetry, the FWHM were 13 mm, 20 mm, and 23 mm, respectively. Secondly, R2 images were converted to dosimetric maps to apply the gamma evaluation method. Comparison using gamma evaluation in the center of the irradiated plane between TPS plan and the dose map from the R2 image was performed. In gamma evaluation, when 3% and 3 mm criteria were used for comparison of the center plane of dose image from TPS and gel dosimetry, the pass ratio of the gamma criterion between calculated dose from the TPS and the dose map of irradiated gels in stereotactic irradiation was 98.6%. In comparison of the center profile and center plane, results of gel dosimetry were shown to have good agreement with the generated treatment plan dosimetric map for stereotactic irradiation.
机译:本研究的目的是研究凝胶剂量测定的小辐射区域,在立体定向放射疗法中。 Pinnacle治疗计划系统(TPS)产生治疗计划,适用于三个不同的圆形照射场:10毫米,15毫米和20毫米。将聚合物凝胶用10-,15-和20mm直径的直径的直径分子照射到6Gy,以在4mV光子束中用于TPS后立体定向辐射。用R 2图像用MRI评估辐照凝胶。首先,比较了TPS计划与R2图像之间的照射中心的线轮廓。在由处理方案计算的剂量的中心轮廓中,半最大(FWHM)的全宽分别为10毫米,15毫米和20毫米准直器,分别为13毫米,19毫米和25mm。在来自凝胶剂量测定法的R 2的中心轮廓中,FWHM分别为13mm,20mm和23mm。其次,将R2图像转换为剂量映射以应用伽马评估方法。进行使用伽马评估在TPS计划之间的辐照平面中心的比较和来自R2图像的剂量图。在γ评价中,当3%和3mm标准用于比较TP和凝胶剂量测定的剂量图像的中心平面时,从TPS计算的剂量与辐照凝胶中的γ型胶质胶片之间的γ标准的通过比例辐照为98.6%。相比之下,中心轮廓和中心平面,显示凝胶剂量测定的结果与所产生的治疗计划剂量测定图具有良好的态度辐照。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号