The multislice spiral computed tomography (MSCT) is famous for the small radiation, large volume scanning and quickly reconstruction, and it becomes the first choice in clinical examination. The upper slicing system is the main components of the optical system in MSCT. This paper focuses on the design of upper slicing slice system and its precision analysis to improve the precision of imaging. The error of slice thickness and ray center by bearings, screw and control system is analyzed and tested. Improving the precision of the upper slicing system contributes to determine the appropriate treatment methods to improve the success rate of treatment.
机译:多层螺旋计算断层扫描(MSCT)以小辐射,大量扫描和快速重建而闻名,成为临床检查的首选。上切片系统是MSCT中光学系统的主要组件。本文侧重于上切片系统的设计及其精度分析,提高了成像精度。分析并测试了通过轴承,螺杆和控制系统的切片厚度和射线中心的误差。提高上切割系统的精度有助于确定适当的治疗方法,以提高治疗成功率。