首页> 外文会议>International Conference on Asian Nuclear Prospects >Preliminary Study for the Passive Containment Cooling System Analysis of the Advanced PWR
【24h】

Preliminary Study for the Passive Containment Cooling System Analysis of the Advanced PWR

机译:先进PWR的被动遏制冷却系统分析的初步研究

获取原文

摘要

The passive containment cooling system (PCCS) is one of the main passive safety systems in the advanced pressurized water reactor (APWR), which will utilize natural phenomena to remove the heat released from the reactor to the environment during the postulated design basic accidents for preventing the overpressure of the containment shell. It is significant for the evaluation on PCCS performance in the design by the numerical simulation with the analysis code. In this paper, a new developed containment analysis code with self-reliance intellectual property rights is used to simulate the containment transients of the advanced pressurized water reactor with the PCCS performance during the postulated LOCA. The sensitivity analyses on some concerned factors are performed. The results show that lower initial humidity in the containment, higher initial environment humidity, higher initial containment temperature and environment temperature will cause higher transient pressure peak in containment during the postulated accident.
机译:被动遏制冷却系统(PCCs)是先进加压水反应器(APWR)中的主要被动安全系统之一,它将利用自然现象,以消除在假定设计基本事故中从反应器释放的热量,以防止容纳壳的超压。通过分析代码的数值模拟对设计中PCCS性能的评估是重要的。本文采用了一种新的发达的Contractment分析码,具有自力更生的知识产权,用于模拟高级加压水反应器的容纳瞬态,在假设基因座期间PCCS性能。进行了一些有关因素的敏感性分析。结果表明,较低的初始湿度在容纳中,更高的初始环境湿度,更高的初始容纳温度和环境温度将在假定事故期间遏制漏气峰值较高。