摘要

A method is established to determine eight kinds of residual solvents in paper package by HS-GC/MS, such as benzene, toluene etc. Response surface method is used to optimize pretreatment temperature and time, the terminal pre-temperature is 100°C, with time 40min. The result reveals that the pretreatment-temperature has a significant impact on peak area and pretreatment-time has no significant influence. The residual solvents in sample was separated using HP-5MS chromatographic column; Flow velocity of He:1ml/min; Inlet temperature:250°C; programmed temperature: keep 2 min at initial temperature of 35°C, then rise to 100°C at a rate of 10°C/min and keep 3min; the total time is 14.5min. The eight kinds of residual solvents can be effectively separated by this method. The linear range was 0.330~7.956mg/m~2 and the correlation coefficient was between 0.995~0.999. The Recovery rate was 99%~114.8% and the relative standard deviation (n=5) was 0.916%~1.333%.
机译:建立一种方法以通过HS-GC / MS确定纸封装中的八种残留溶剂,例如苯,甲苯等。响应面方法用于优化预处理温度和时间,终端预热为100°C,随着时间的推移40分钟。结果表明,预处理温度对峰面积产生重大影响,预处理时间没有显着影响。使用HP-5MS色谱柱分离样品中的残留溶剂; HE:1ml / min的流速;入口温度:250°C;编程温度:保持2分钟的初始温度35°C,然后以10°C / min的速率升至100°C并保持3分钟;总时间为14.5min。通过该方法可以有效地分离八种残留溶剂。线性范围为0.330〜7.956mg / m〜2,相关系数在0.995〜0.999之间。回收率为99%〜114.8%,相对标准偏差(n = 5)为0.916%〜1.333%。