首页> 外文会议>International Conference on Advances in Energy Engineering >Wind Tunnel Experimental Study on Influence Factors of Evaporative HeatTransfer of Porous Building Material
【24h】

Wind Tunnel Experimental Study on Influence Factors of Evaporative HeatTransfer of Porous Building Material

机译:风洞隧道实验研究多孔建筑材料蒸发热传输影响因素

获取原文

摘要

With Orthogonal experimental method, an experimental study on influence factors of evaporative heat transfer of aerated concrete under a certain moisture content was carried out in the hot-humid climatic wind tunnel. The factors concerned include four meteorological factors and sample thickness. Measured from the impact of significant and persistent on evaporative heat transfer, solar radiation is the greatest influence factor, then followed by the sample thickness, the air velocity is in the third order, and the last factor is ambient air temperature, the air relative humidity and the interaction of air temperature with it have no statistically significant influence. Through the analyze we know that the most dramatically significant level of infrared power, air velocity, air" temperature and sample thickness on the evaporative heat transfer were 400 w/m~2, 1.5 m/s, 30°C and 100mm respectively.
机译:具有正交实验方法,在热潮湿气候风隧道中进行了在一定水分含量下蒸发混凝土蒸发热传递影响因素的实验研究。有关因素包括四种气象因素和样品厚度。从蒸发传热的显着和持续的影响来测量,太阳辐射是最大的影响因素,然后是样品厚度,空气速度是第三阶的,并且最后一个因子是环境空气温度,空气相对湿度并且空气温度与其的相互作用没有统计学上显着的影响。通过分析我们知道,蒸发热传递上最大显着的红外功率,空气速度,空气“温度和样品厚度分别为400W / m〜2,1.5米/米,30°C和100mm。