首页> 外文会议>CIE "Light Quanlity and Energy Efficiency" >GONIOSPECTRORADIOMETRY FOR ACCURATE MEASUREMENT OF SPATIALLY AVERAGED CHROMATICITY
【24h】

GONIOSPECTRORADIOMETRY FOR ACCURATE MEASUREMENT OF SPATIALLY AVERAGED CHROMATICITY

机译:用于精确测量空间平均色度的GonioSpectrodiom测量

获取原文

摘要

In order to make accurate measurement for spatially averaged chromaticity, we made a theoretical analysis and simulation on weighted mean defined in published standards and rigorous method by goniospectroradiometry. The simulation results are consistent with theoretical analysis very well. It is found the method of weighted mean will provide sufficient accuracy for color distributions with a good uniformity. However, it will result in large errors as the nonuniformity of color distribution increases. So, it is recommended to adopt goniospectroradiometry for accurate measurement of spatially averaged chromaticity.
机译:为了准确测量空间平均的色度,我们通过GonioSpectRoRadiometry在公布标准和严格方法中定义了对加权平均值的理论分析和仿真。仿真结果与理论分析一致。发现加权平均值的方法将为具有良好均匀性的颜色分布提供足够的精度。然而,由于颜色分布的不均匀性增加,它将导致大的误差。因此,建议采用GONIOPCTRORADIOR法以精确测量空间平均的色度。