Determination of ultra trace of heavy metals in water by ICP-AES based on magnetic enrichment

机译:基于磁性富集的ICP-AES测定水中重金属超痕量

获取原文

摘要

Anew method has been established for the pre-enrichment of trace heavy metals(lead(II), cadmium(II), chromium(VI) and nickel(II)) by magnetic iron oxide(core) / zirconium dioxide(shell) and determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) in water samples. The factors affecting the separation and pre-enrichment of analytes such as amounts of magnetic iron oxide / zirconium dioxide, elution time and interfering ions were studied. The detection limits of the method (3a) were 13.5ng/mL, 1.01ng/mL, 2.94ng/mL and 3.31mg/L respectively for lead(II), cadmium(II), chromium(VI) and nickel(II). The results showed that this method was simple, accurate, and sensitive which could be applied for the pre-enrichment, separation and determination of trace heavy metals in all kinds of water samples.
机译:通过磁性氧化铁(核心)/锆(壳)和测定,已经建立了对痕量重金属(铅(II),镉(II),铬(II),铬(II))的预富集进行预富集的方法通过电感耦合等离子体原子发射光谱法(ICP-AES)在水样中。研究了影响分析物的分离和预富集的因素,例如磁性氧化铁/锆的量,洗脱时间和干扰离子。方法(3a)的检测限为13.5ng / ml,1.01ng / ml,2.94ng / ml,2.94ng / ml和3.31mg / L,铅(II),镉(II),铬(VI)和镍(II) 。结果表明,该方法简单,准确,敏感,可用于各种水样中痕量重金属的预富集,分离和测定。