The heating source of a district heating (DH) system in Beijing was reformed from coal boilers to a groundwater heat pump (GWHP) system and a sewage source heat pump (SSHP) system. This study aims to evaluate the actual performance and benefits of two water-source heat pump systems. We found total energy savings and primary energy saving rate due to the retrofit to be 950 tons of standard coal equivalent (TCE) every year and 34.6%, respectively. Field test results indicated the necessity of system performance improvement. Appropriate approaches to improve the system performance were discussed.
机译:北京地区供暖(DH)系统的加热源从煤锅炉改革为地下水热泵(GWHP)系统和污水源热泵(SSHP)系统。本研究旨在评估两个水源热泵系统的实际性能和益处。我们发现总节能和初级节能率由于每年950吨标杆煤量(TCE)分别为34.6%。现场测试结果表明系统性能改进的必要性。讨论了改善系统性能的适当方法。