Electromagnetic flow meters are widely used in two-phase or multi-phase flow measurements in recent years. In this paper, simulation model is established to study the flow meter response characteristics which exist a non-conductive body (oil bubble) in the fluid by use finite element software ANSYS. We analyze different electrode size impact on the response characteristics of electromagnetic flow meter in the measurement of two-phase or multi-phase flow which includes non-conductive material in the fluid, which provides reference for design of the sensor electrode sizes, and provides a theoretical basis for error analysis measuring two-phase or multi-phase flow under different electrode sizes of electromagnetic flowmeter.
机译:电磁流量计近年来广泛应用于两相或多相流量测量。在本文中,建立了模拟模型,以研究流体中存在不导电体(油泡)的流量计响应特性,使用有限元软件Ansys。我们分析了对电磁流量计的响应特性的不同电极尺寸的影响,该电磁流量计的响应特性包括流体中的非导电材料,这为传感器电极尺寸的设计提供了参考,并提供了一个电磁流量计不同电极尺寸下测量两相或多相流的误差分析的理论依据。