首页> 外文会议>International Conference on Energy, Environment and Sustainable Development >Coupled Heat Transfer Analysis of Piston Crown, Piston Rings and Cylinder Liner
【24h】

Coupled Heat Transfer Analysis of Piston Crown, Piston Rings and Cylinder Liner

机译:活塞冠的耦合传热分析,活塞环和气缸套

获取原文

摘要

MAN Diesel's 6S50MC-C disel is a two-stroke marine diesel engine. As the boundary conditions of temperature field distribution, the mean temperature and mean heat transfer coefficient are calculated firstly. The coupled heat transfer of piston crown, piston rings and cylinder liner are analyzed. The steady temperature field and the transient heat transfer under starting condition of diesel engine are obtained in ANSYS. Maximum temperature is 413.55°C in the top surface edge of the piston crown. 59.5% of the total heat from high-temperature fuel gas heat is absorbed by the cooling oil. The temperature of piston crown is effectively reduced by shaker cooling. The load of diesel engine should be increased slowly to prevent stress concentration. To reduce the destructive effect, enhancing cooling and warming up the main engine are requested.
机译:Man Diesel的6S50MC-C Disel是一款双行程海洋柴油发动机。作为温度场分布的边界条件,首先计算平均温度和平均传热系数。分析活塞冠,活塞环和汽缸套的耦合传热。在ANSYS中获得稳定温度场和柴油发动机起始条件下的瞬态传热。最高温度在活塞冠的顶部表面边缘中为413.55°C。从高温燃料气体热量的59.5%被冷却油吸收。活塞冠的温度通过振动器冷却有效地减少。柴油发动机的负荷应缓慢增加以防止应力浓度。为了降低破坏性效果,请求加强冷却和预热主发动机。