Thermal energy recovery from wastewater can be established from centralized wastewater treatment plants and sewage systems. Little attention has been given to In-house wastewater; although it can potentially pave way towards a sustainable heat source. The study was conducted inside student hostels in Berlin, in which water supply, wastewater, and room temperatures variations were observed during winter for one month. It was shown that water supply temperature has insignificant effect on the variations of in-house wastewater temperature as compared to room temperature and water use. The daily average temperature of the in-house wastewater was in a range of 11°C to 20°C, with an average of about 15°C. It was illustrated that by selecting suitable combination of heat exchanger and heat pump, about 40 kWh/h (917 kWh/day) average inhouse wastewater thermal heat can be recovered and about 230 {EUR}/day saved. This can contribute to reduction of energy needed for hot water provision by about 30% in the targeted hostels.
机译:可以从集中废水处理厂和污水系统建立废水的热能回收。一点关注内部的废水;虽然它可能潜入可持续的热源。该研究在柏林的学生宿舍进行,其中在冬季期间观察到供水,废水和室温变化一个月。结果表明,与室温和用水相比,供水温度对内部废水温度的变化具有微不足道的影响。内部废水的每日平均温度在11°C至20℃的范围内,平均约为15℃。示出了通过选择热交换器和热泵的合适组合,可以回收约40kWh / h(917 kWh /日)平均余量热量,并节省约230欧元/日。这可以有助于将热水供水所需的能量降低约30%在目标宿舍。