首页> 外文会议>International Conference on Engineering Materials, Energy, Management and Control >Operating Modes of the Solar Assisted Drainwater System for Ground Source Heat Pump
【24h】

Operating Modes of the Solar Assisted Drainwater System for Ground Source Heat Pump

机译:用于地源热泵太阳能辅助排水系统的操作模式

获取原文

摘要

To extend the area in applications of solar heat pump and drainwater heat recovery, the gravity film exchanger was employed to establish the solar assisted drainwater heat pump system. In this paper, two gravity film exchangers were assembled in the hybrid heat pump system to discuss the effect of water distribution ratio in two exchangers on the electric power complement and outlet water temperature of the condenser. The technology of Matlab/Simulink was used in modeling and simulations of the system by the performance curves and performance parameters of the corresponding system components. In the designing processes, the dynamic characteristics can be predicted, and the optimal operating conditions can also be concluded that appropriate water distribution ratio should be selected respectively for higher outlet temperature of the condenser or lower electric power complement.
机译:为了延长太阳能热泵和排水热回收的应用领域,采用重力膜交换器来建立太阳能辅助排水热泵系统。在本文中,在混合热泵系统中组装了两种重力薄膜交换器,讨论了两种交换机中的水分配比对冷凝器的电力补体和出口水温的影响。 MATLAB / SIMULINK技术用于通过相应系统组件的性能曲线和性能参数建模和模拟系统。在设计过程中,可以预测动态特性,并且还可以得出最佳操作条件,即应分别选择适当的水分布比,以便为冷凝器的较高出口温度或更低的电力补充。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号