Experimental investigations of the performance of a solar-ground source heat pump system operated in heating modes

机译:在加热模式下运行的太阳能地源热泵系统性能的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

Solar-ground source heat pump system (SGSHPS) is a new type of high efficiency, energy saving and environmental protection air-conditioning technology. In this paper, experimental studies and numerical simulation on the performance of a SGSHPS operated in different heating modes were carried out. The experimental system was installed in Nanjing of China and solar collectors were coupled with ground heat exchangers (GHE) through an insulated water tank. Four operation modes including ground source heat pump (GSHP), combined operation mode, day and night alternate operation mode and solar U-tube feeding heat alternate operation mode were investigated during winter season. The heat pump performance, solar collecting performance and borehole wall temperature variations were analyzed and compared for various modes. The experimental results indicate that for the combined operation mode, the system operation efficiency during day can be improved by the assistance of solar energy, and the excess solar energy collected during day can be stored in ground by the GHE to improve the operation performance of GSHP during night. The proportions of heat source burdened by solar and geothermal energy are 43.3% and 50.2% respectively. For the alternate operation modes, the temperature resumption of ground surrounding the GHE can be well achieved due to the intermittent heat extraction of GHE or feeding solar heat into ground and thus the overall utilization efficiency of solar and geothermal energy can be improved greatly. During the whole experimental period, the average COPs are 2.37 and 2.72 for GSHP and SAHP operation mode respectively, and the corresponding parameters are 2.69, 2.65 and 2.56 for the combined operation mode, day and night alternate operation mode and solar U-tube feeding heat alternate operation mode, respectively. The average solar collecting efficiency are 43.6%, 47.3% and 38.8% for the combined operation mode, SAHP operation mode and solar U-tube feeding heat operation mode, respectively. Based on the unit modeling, a dynamic simulation program was constructed to investigate the seasonal performance of the SGSHPS operated in different heating modes, the simulation results show that the seasonal average COP are 3.67, 3.64, 3.52 and 3.48 for the combined operation, day and night alternate operation, solar U-tube feeding heat and GSHP mode, respectively. From the view of improving the overall efficiency and increasing heat source fraction of solar energy, the combined operation mode is the best. (C) 2014 Elsevier B.V. All rights reserved.
机译:太阳能地源热泵系统(SGSHPS)是一种新型的高效,节能和环保的空调技术。在本文中,对在不同加热模式下运行的SGSHPS的性能进行了实验研究和数值模拟。该实验系统安装在中国南京,太阳能集热器通过隔热水箱与地面热交换器(GHE)耦合。冬季研究了地源热泵(GSHP),联合运行模式,日夜交替运行模式和太阳能U型管供热交替运行模式这四种运行模式。分析并比较了各种模式下的热泵性能,太阳能收集性能和井壁温度变化。实验结果表明,对于联合运行模式,利用太阳能可以提高白天的系统运行效率,利用GHE可以将白天收集到的多余太阳能存储在地下,从而提高了GSHP的运行性能。在晚上。太阳能和地热能负担的热源比例分别为43.3%和50.2%。对于交替运行模式,由于间歇性地提取GHE或将太阳能供入地下,可以很好地实现GHE周围地面的温度恢复,从而可以大大提高太阳能和地热能的综合利用效率。在整个实验期间,GSHP和SAHP运行模式的平均COP分别为2.37和2.72,组合运行模式,昼夜交替运行模式和太阳能U型管供热的相应参数分别为2.69、2.65和2.56。分别为备用操作模式。联合运行模式,SAHP运行模式和太阳能U型管供热运行模式的平均集热效率分别为43.6%,47.3%和38.8%。基于单元建模,构建了一个动态模拟程序来研究在不同供热模式下运行的SGSHPS的季节性性能,模拟结果表明,组合运行,日和天的季节性平均COP为3.67、3.64、3.52和3.48。夜间交替运行,分别采用太阳能U型管供热和GSHP模式。从提高太阳能的整体效率和增加热源比例的角度来看,组合运行方式是最好的。 (C)2014 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号