首页> 外文会议>International Conference on Frontiers of Manufacturing Science and Measuring Technology >Development of Experimental Apparatus for Diaphragm Gas Meter in the limiting temperature conditions
【24h】

Development of Experimental Apparatus for Diaphragm Gas Meter in the limiting temperature conditions

机译:膜片燃气表实验装置的研制在限制温度条件下

获取原文

摘要

This paper presents the basic architecture and working principle of diaphragm gas meter experimental apparatus in the limiting temperature conditions. A double-standard test method with critical flow nozzle as main standard and roots flow meter as reference standard has been proposed. Indicating error and pressure loss characteristic at different temperatures are obtained by experimental research on the metrological characteristics of diaphragm gas meters (G2.5) which are produced by numerous corporations under the condition of non-reference temperature. The experimental results show that the indicating value of diaphragm gas meters under high temperatures is basically accurate, but the metrological property is a little patchy in terms of quality at low temperatures. The maximum indication error of part measuring instruments is up to 16%.
机译:本文介绍了隔膜燃气表实验装置在限制温度条件下的基本架构和工作原理。提出了一种作为主要标准和根流量计作为主要标准的双标准测试方法,作为参考标准。在不同温度下的实验研究获得了不同温度的误差和压力损失特性,这是关于在非参考温度的条件下由众多公司生产的膜片煤气表(G2.5)的测量性特性。实验结果表明,高温下膜片煤气表的指示值基本上是准确的,但在低温下质量方面的计量性质有点差异。零件测量仪器的最大指示误差高达16%。