At present, according to Code for Design of Steel Structures(GB50017-2003), for axially loaded column with plated column base, the column bases are considered as hinged supports, but possess actually remarkable rotational restraint. The effective length of columns can be decreased when the constraint function of plated column base is considered in calculation. The calculation of effective length factor of columns is usually according to the approximate formula which is deduced by the rotational stiffness. Axially loaded column plated column base models were established with the finite element software, the effective length factor of columns was obtained by the method which can avoid calculating rotational stiffness of plated column bases, the influence factors on the rotational restraint of axially loaded column plated column base, such as the base plate thickness, the diameter of anchors, the column section size were also analyzed in this paper.
机译:目前,根据钢结构设计的代码(GB50017-2003),对于具有电镀柱底座的轴向装载的柱,柱碱被认为是铰接支撑,但实际上具有显着的旋转束缚。当在计算中考虑电镀柱底座的约束函数时,可以降低柱的有效长度。柱的有效长度因子的计算通常根据旋转刚度推导的近似公式。建立轴向加载的柱镀柱基础型号,采用有限元软件建立,通过该方法获得柱的有效长度因子,该方法可以避免计算镀柱底座的旋转刚度,对轴向装载柱镀柱旋转约束的影响因素基础,如底板厚度,锚点的直径,本文还分析了柱截面尺寸。