摘要

The semi-rigid steel frame-composite steel plate shear wall structure (SCSW) effectively improves the lateral stiffness of shear wall, making it possible to use the semi-rigid joint. In order to study the plastic failure mechanism of SCSW, a plastic model is established, in which the effects of the rotations of semi-rigid joints and yield deformations of infill steel walls on the energy consumption are considered. Based on that, a design method for the lateral ultimate strength is put forward and a nonlinear FEM model is setup using ANSYS. Through the comparison between plastic analysis results with the finite element results, it is shown that the plastic analysis method is feasible and has a safe redundancy.
机译:半刚性钢框架复合钢板剪切墙体结构(SCSW)有效地提高了剪力墙的横向刚度,使得可以使用半刚性接头。为了研究SCSW的塑料失效机理,建立了一种塑料模型,其中考虑了半刚性接头的旋转和填充钢壁的屈服变形对能量消耗的影响。基于此,提出了一种用于横向极限强度的设计方法,并使用ANSYS设置非线性有限元模型。通过塑性分析结果与有限元结果的比较,结果表明塑料分析方法是可行的并且具有安全的冗余。