The diagonal cracks in the web of box girder bridge which caused by excessive loss of vertical prestressed tensioning force are particularly common. In order to effectively detect the real force of the vertical prestressed rebars. Take the exposed section of the vertical prestressed rebar as an analysis entity, and take the rebar as a rigid body; the anchoring segment is simulated by an annular outrigger and an annular elastic support. When vertical pretress tension changes, the stiffness of elastic support and the vibration frequency also change accordingly, the change of the value of tensile force can be reflected by the vibration frequency. Combined with the model test data, the nonlinear elastic parameter model between the finish deformed rebar vertical tensioning force T and the space elastic support stiffness K is established. The validity of the method was checked by extension test. The study indicate that this method is accurate, fast and convenient for engineering applications, can effectively improve the construction quality.
机译:由垂直预应力张紧力的过度损失引起的箱梁桥网中的对角线裂缝特别常见。为了有效地检测垂直预应力钢筋的真正力量。将垂直预应力钢筋的暴露部分作为分析实体,并将钢筋作为刚体;锚固段由环形支腿和环形弹性支撑件模拟。当垂直倒立张力变化时,弹性支撑件的刚度和振动频率也相应地改变,可以通过振动频率反射拉伸力的值的变化。结合模型测试数据,建立了结束变形钢筋垂直张紧力T和空间弹性支撑刚度K之间的非线性弹性参数模型。通过扩展测试检查该方法的有效性。该研究表明,该方法是准确,快捷方便的工程应用,可以有效地提高施工质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号