首页> 外文会议>International Conference on Energy and Environmental Protection >Daylight Factor for Energy Saving in Retrofitting Institutional Building
【24h】

Daylight Factor for Energy Saving in Retrofitting Institutional Building

机译:改造制度建设中节能的日光因素

获取原文

摘要

In Malaysia, lighting is the second electric power consumption after air conditioning and it is increasing every year. Most of the lighting design standard for building in Malaysia is based on MS1525, and this being taken without further measure on daylight consideration. Movement from inefficient and unsustainable energy practice to more energy efficient initiatives is vital for building. Universiti Teknologi Malaysia as one of the major institutional building is consuming 9 to 16 million kWh per year. Thus, about 20% of energy consumed was from artificial lighting. This paper aim to highlights the cost benefit study of lighting retrofit, which integrates the utilization of daylight into existing building. Data for this study was obtained through illumination in-situ measurement on two types of artificial lighting with the inclusive of day lighting before and after lighting retrofit. The measurement was conducted in a typical building in Block C09 of Universiti Teknologi Malaysia (UTM). Annual saving and payback period were analysed from the collected data. It is estimated that total energy consumption decreasing around 47.7% over a year from 84,232kWh to 44,014kWh by retrofitted the fluorescent T8, 36W with fluorescent T5, 25W. The estimated total annual electricity bill saving is at RM11,073 (USD3500.00). The return in retrofitting cost is at 2.5 years payback period. The payback analysis portray that lighting design is best integrated with daylight. The significant amount of saving in energy consumption and the cost of retrofit is obtained by integrating daylight as a source of lighting for interior space.
机译:在马来西亚,照明是空调后的第二次电力消耗,每年都在增加。马来西亚建筑的大部分照明设计标准都是基于MS1525,而这仍然没有进一步衡量日光考虑。从低效和不可持续的能源实践到更节能举措的运动对建筑至关重要。马来西亚大学大学,作为主要的机构建设之一,每年消耗9至1600万千瓦时。因此,消耗的约20%的能量是从人工照明中。本文旨在突出照明改造的成本效益研究,将日光利用融为现有建筑物。本研究的数据是通过在透明改装之前和之后的两种人工灯上的两种人造光线上的照明测量获得的。测量在马来西亚(UTM)块C09的典型建筑中进行。从收集的数据分析年度储蓄和投资回收期。据估计,通过改装荧光T5,25W的荧光T8,36W,总能耗从84,232kWh减少到44,014kWH约47.7%。估计的年度电费票据储蓄总额为RM11,073(3500.00美元)。回报率成本为2.5年的投资回收期。回报分析描绘了照明设计与日光最好。通过将日光作为室内空间的照明来源将日光作为照明来源获得了大量的能耗和改造成本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号