Comparison of 3D and 2D Breast Density Estimation from Synthetic Ultrasound Tomography Images and Digital Mammograms of Anthropomorphic Software Breast Phantoms

机译:拟颞软件乳房阵线合成超声断层扫描图像和数字乳房X线图的3D和2D乳房密度估计的比较

获取原文
获取外文期刊封面目录资料

摘要

Breast density descriptors were estimated from ultrasound tomography (UST) and digital mammogram (DM) images of 46 anthropomorphic software breast phantoms. Each phantom simulated a 450 ml or 700 ml breast with volumetric percent density (PD) values between 10% and 50%. The UST based volumetric breast density (VBD) estimates were calculated by thresholding the reconstructed UST images. Percent density (PD) values from DM images were estimated interactively by a clinical breast radiologist using Cumulus software. Such obtained UST VBD and Cumulus PD estimates were compared with the ground truth VBD values available from phantoms. The UST VBD values showed a high correlation with the ground truth, as evidenced by the Pearson correlation coefficient of r=0.93. The Cumulus PD values also showed a high correlation with the ground truth (r=0.84), as well as with the UST VBD values (r=0.78). The consistency in measuring the UST VBD and Cumulus PD values was analyzed using the standard error of the estimation by linear regression (σ_E). The σ_E value for Cumulus PD was 1.5 times higher compared to the UST VBD (6.54 vs. 4.21). The σ_E calculated from two repeated Cumulus estimation sessions (σ_E=4.66) was comparable with the UST. Potential sources of the observed errors in density measurement are the use of global thresholding and (for Cumulus) the human observer variability. This preliminary study of simulated phantom UST images showed promise for non-invasive estimation of breast density.
机译:从超声断层扫描(UST)和数字乳房X线图(DM)图像估算了乳房密度描述函数的46个拟方针软件乳房映像。每个幻影模拟450ml或700ml乳房,体积百分比密度(Pd)值介于10%和50%之间。通过阈值计算重建的UST图像来计算基于UST基的体积乳收密度(VBD)估计。使用积云软件的临床乳房放射科医师相互作用地估计来自DM图像的百分比(PD)值。将如此获得的UST VBD和积云PD估计与来自幻像中可获得的地面真理VBD值进行比较。 UST VBD值与地面真理显示出高的相关性,如r = 0.93的Pearson相关系数所证明的。积分PD值还显示出与地面真理(R = 0.84)以及UST VBD值(R = 0.78)的高相关。使用线性回归(Σ_E)的标准误差分析测量UST VBD和积云PD值的一致性。与UST VBD(6.54对4.21)相比,积云PD的σ_e值比较高的1.5倍。从两个重复的巨积估计会话(σ_e= 4.66)计算的σ_e与UST相当。密度测量中观察到的误差的潜在来源是使用全局阈值和(用于积压)人类观察者可变性。这种模拟幻影UST图像的初步研究显示了乳房密度的非侵入性估计的承诺。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号