This work examines the use of a detectability index to control an Automatic Exposure Control (AEC) system for an amorphous-Selenium digital mammography detector. The default AEC mode for the system was evaluated using homogeneous poly(methyl methacrylate) (PMMA) plates of thickness 20, 40, 60 and 70 mm to find the tube potential and anode/filter settings selected by the system. Detectability index (d') using a non-prewhitened model observer with eye filter (NPWE) was calculated for these beam qualities as a function of air kerma at the detector. AEC settings were calculated that gave constant d' as a function of beam quality for a homogeneous background; a target d' was used that ensured the system passed the achievable image quality criterion for the 0.1 mm diameter disc in the European Guidelines. Threshold gold thickness was measured using the CDMAM test object as a function of beam quality for the AEC mode, which held pixel value (PV) constant, and for the constant d' mode. Threshold gold thickness for the 0.1 mm disc increased by a factor of 2.18 for the constant PV mode, while constant d' mode held threshold gold thickness constant to within 7% and signal-difference-to-noise-ratio (SdNR) constant to within 5%. The constant d' settings derived for homogeneous images were then applied to a phantom with a structured background. Threshold gold thickness for the 0.13 mm disc increased by a factor of 1.90 for the constant PV mode, while constant d' mode held threshold gold thickness constant within 38% for 0.13 mm disk.
机译:这项工作探讨了使用可检测性指数来控制用于无定形硒数字乳房X线摄影探测器的自动曝光控制(AEC)系统。使用厚度20,40,60和70mm的均匀聚(甲基丙烯酸甲酯)(PMMA)板来评估系统的默认AEC模式,以找到由系统选择的管电位和阳极/过滤器设置。使用具有眼睛滤光器(NPWE)的非预霍化模型观测器的可检测性指数(D')为这些光束质量计算作为检测器的空气Kerma的功能。计算AEC设置,以恒定的D'作为均匀背景的光束质量的函数;使用目标D',确保系统通过欧洲指南中可实现的0.1毫米直径光盘可实现的图像质量标准。使用CDMAM测试对象测量阈值金厚度作为AEC模式的光束质量的函数,其保持像素值(PV)常数,并且用于恒定的D'模式。 0.1 mm盘的阈值金厚度对于恒定的PV模式增加了2.18的因子,而恒定的D'模式将阈值金厚度保持在7%内,并且信号差分与噪声比(SDNR)恒定5%。然后将用于均匀图像的常数D'设置应用于具有结构化背景的幻象。对于0.13 mm盘的阈值金厚度为恒定PV模式增加了1.90的因子,而恒定的D'模式保持阈值金厚度恒定在38%以内为0.13 mm。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号