摘要

Comparing with conventional mechanical shot peening (SP) technique, water cavitation peening (WCP) experiments of Almen strips were carried out on a self-manufactured equipment. The results show that WCP demonstrates a wide range of standoff distance (SD) that from the nozzle to the surface of the object. By measuring the colour changes of the Fuji pressure sensing film, over 110 MPa impacting pressure was detected, which is resulted from the bubbles blasting on the sample surface when the SD is from 65 to 100 mm under 40 MPa of operating pressure. 600 MPa compressive residual stress achieved on the surface of the Almen strips after WCPed for 32 min. The depth of the zone affected by the compressive residual stress is about 100 μm. The highest residual stress appears in the top surface layer, while in case of SP it appears in the subsurface. Compared to SP, WCP is capable to get rather smoother surface and cause less deformation of the testing sheet, simultaneously.
机译:与传统机械喷丸喷丸(SP)技术相比,在自制造的设备上进行了ALMEN条带的防水喷丸(WCP)实验。结果表明,WCP通过喷嘴到物体表面的宽范围的支座距离(SD)。通过测量FUJI压力传感膜的颜色变化,检测到超过110MPa的撞击压力,当SD在40MPa的操作压力下为65至100mm时,由于样品表面上的气泡喷丸产生。 600MPa压缩残余应力在WCPED 32分钟后在Almen条的表面上实现。受压缩残余应力影响的区域的深度约为100μm。最高的残余应力出现在顶部表面层中,而在SP的情况下,它出现在地下。与SP相比,WCP能够相当更平滑的表面,并同时导致测试表的变形。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号