首页> 外文会议>International Conference on Civil Engineering and Transportation >Testing and Analysis on Thermal Performance for Prefabricated Thermal Insulation Composite Wall Panel of an Office Building
【24h】

Testing and Analysis on Thermal Performance for Prefabricated Thermal Insulation Composite Wall Panel of an Office Building

机译:办公楼预制隔热复合墙板的热性能测试与分析

获取原文

摘要

The main objective of this study is to explore prefabricated thermal insulation composite wall's thermal performance in the project. Using infrared thermal imager and multi-point heat meter takes a test on office building envelope. The test results showed that the composite wall temperature change delay of 3 hours 12 minutes, the temperature change attenuation of 2.5°C; The composite board exterior wall surface temperature attenuation is larger and the thermal stability of the structure is perfect; thermal bridge is the main reason for reducing the average thermal resistance of the wall.
机译:本研究的主要目的是探索项目中预制的隔热复合墙体的热性能。使用红外线热成像仪和多点热量表在办公大楼信封上进行测试。试验结果表明,复合壁温变化延迟3小时12分钟,温度变化衰减为2.5°C;复合板外墙表面温度衰减较大,结构的热稳定性是完美的;热桥是降低墙壁平均热阻的主要原因。