Different Designs for a Polarization State Detector Based on Division-of-Amplitude

机译:基于幅度的偏振态检测器的不同设计

获取原文

摘要

A polarization state detector (PSD) measures all parameters of the state of polarization of the detected light. The state of polarization is described by four Stokes parameters while the total phase of the light is discarded. Only four intensity measurements are needed to measure the four Stokes parameters even though the Stokes vector is defined by six intensity measurements. By using a special optical design with four photodetectors, these measurements can be conducted simultaneously. To measure the Stokes vector with high accuracy, a special beam splitter has been proposed in the literature imposing constraints on the reflectance, transmittance and retardance of the p- and s-polarized reflected and transmitted wave. Later on, several alternative designs have been proposed using two or more retarders and ordinary beam splitters. In this report another alternative design of the PSD is presented. In fact, only two instead of four waveplates are needed to get optimal results for ordinary beam splitters with suboptimal optical properties.
机译:偏振态检测器(PSD)测量检测到的光的偏振状态的所有参数。在四个斯托克斯参数中描述了极化状态,而丢弃光的总阶段。即使Stokes向量由六个强度测量定义,也只需要四个强度测量来测量四个Stokes参数。通过使用具有四个光电探测器的特殊光学设计,可以同时进行这些测量。为了测量具有高精度的斯托克斯向量,在文献中提出了一种特殊的分束器,在对P和S偏振的反射和透射波的反射率,透射率和延迟的限制上施加约束。后来,已经提出了使用两个或更多个延迟器和普通分束器的替代设计。在本报告中,呈现了PSD的另一种替代设计。实际上,只需要两个而不是四个波动来获得具有次优光学性质的普通束分离器的最佳结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号