SMELT SPOUT CORROSION IN A RECOVERY BOILER

机译:在恢复锅炉中闻到喷口腐蚀

获取原文

摘要

Severe corrosion led to an in-service failure of one of the six spouts on a recovery boiler at Cenibra. The failure resulted in a large amount of cooling water entering the boiler and contacting smelt around the spout opening, but fortunately no smelt-water explosion occurred. An extensive investigation was conducted to determine the causes of the spout failure. It was concluded that the failure was caused by insufficient cooling water flow to the smelt spout, which, in turn, was caused by a sequence of events that occurred after a general black out of an electrical energy system at the mill. The experience has led to the development and placement of operating and maintenance procedures that ensure adequate cooling water flow to smelt spouts to prevent future failures.
机译:严重的腐蚀导致在Cenibra的回收锅炉上的六个喷口中的一个的换挡失效。故障导致大量的冷却水进入锅炉并接触闻到喷口开口周围,但幸运的是没有发生熔炼水爆炸。进行了广泛的调查以确定喷口失效的原因。结论是,失败是由于冷却水流量不足引起的熔喷喷口,这反过来又由在磨机中的电能系统中的一般黑色外部发生后发生的一系列事件引起的。这些经验导致了操作和维护程序的开发和放置,确保了充足的冷却水流,以防止未来的失败。