首页> 外文会议>International conference on the physics of reactors >Control Rod Malfunction at the NRAD Reactor
【24h】

Control Rod Malfunction at the NRAD Reactor

机译:NRAD反应器的控制杆故障

获取原文

摘要

The neutron Radiography Reactor (NRAD) is a training, research, and isotope (TRIGA) reactor located at the INL. The reactor is normally shut down by the insertion of three control rods that drop into the core when power is removed from electromagnets. During a routine shutdown, indicator lights on the console showed that one of the control rods was not inserted. It was initially thought that the indicator lights were in error because of a limit switch that was out of adjustment. Through further testing, it was determined that the control rod did not drop when the scram switch was initially pressed. The control rod anomaly led to a six month shutdown of the reactor and an in depth investigation of the reactor protective system. The investigation looked into: scram switch operation, console modifications, and control rod drive mechanisms. A number of latent issues were discovered and corrected during the investigation. The cause of the control rod malfunction was found to be a buildup of corrosion in the control rod drive mechanism. The investigation resulted in modifications to equipment, changes to both operation and maintenance procedures, and additional training. No reoccurrences of the problem have been observed since corrective actions were implemented.
机译:中子造影反应器(NRAD)是位于INL的训练,研究和同位素(Triga)反应器。当从电磁铁中除去电源时,反应器通常通过插入芯片中的三个控制杆关闭。在常规关机期间,控制台上的指示灯显示,未插入一个控制杆。最初认为指标灯由于超出调整的限位开关而出现错误。通过进一步的测试,确定当最初按下扰流开关时控制杆没有下降。控制杆异常导致反应器的六个月关闭和对反应器保护系统的深度研究。调查研究:SCRAM开关操作,控制台修改和控制杆驱动机构。在调查期间发现和纠正了许多潜在问题。发现控制杆发生故障的原因是控制杆驱动机构中的腐蚀的堆积。调查导致对设备进行修改,改变操作和维护程序以及额外的培训。由于实施了纠正措施,因此未被观察到该问题的再发产。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号