Since the view direction of an oblique-viewing endoscope can be changed by rotating the scope cylinder to obtain a larger field of view, the rotation angle of the scope cylinder is one of the parameters in its camera model. In order to perform the augmented reality visualization in the surgery using the oblique-viewing endoscope, tracking of the rotation angle is required to determine the view direction. The optical tracking markers or the rotary-encoder have been used for the rotation tacking in the previous studies. However, the additional components attached to the endoscope can be obstructive during the surgery. We propose the rotation tracking method without any additional components based on detection of the wedge mark in the endoscopic image, which indicates the cylinder angle. In the experiment, the difference of the proposed method from the rotary encoder used as the gold standard was less than 1.5 degrees.
机译:由于可以通过旋转范围滚筒来获得倾斜观察内窥镜的视图以获得更大的视场来改变,因此范围滚筒的旋转角度是其相机模型中的参数之一。为了使用斜视内窥镜在手术中进行增强现实可视化,需要跟踪旋转角度来确定视图方向。光学跟踪标记或旋转编码器已被用于先前研究中的旋转旋转。然而,在手术期间,附着于内窥镜的附加的附加成分可能是妨碍的。我们提出了基于内窥镜图像中的楔形标记的任何附加部件的旋转跟踪方法,其指示汽缸角。在实验中,当黄金标准使用的旋转编码器中提出的方法的差异小于1.5度。