首页> 外文会议>International Conference on Mechanical and Electrical Technology >Heat Transfer Enhancement Due To V-Shaped Perforated Blocks in a Solar Air Heater Duct
【24h】

Heat Transfer Enhancement Due To V-Shaped Perforated Blocks in a Solar Air Heater Duct

机译:由于太阳能空气加热器管道中的V形穿孔块引起的传热增强

获取原文

摘要

An experimental study of enhancement of heat transfer due to V-shaped perforated blockages attached to the heated surface has been presented in this paper. The duct equipped with perforated V-blocks had an aspect ratio (W/H) of 12, relative blockage height ratio (e/H) of 0.8, angle of attack (α) of 60° and open area ratio (β) of 20%, while relative pitch ratio (P/e) was varied from 4 to 12. The values of Nusselt number and friction factor of the duct with blockages were compared with values of Nusselt number and friction factor of the smooth duct operating under similar experimental conditions. It was found that there was a significant effect on the Nusselt number ratio and friction factor ratio when the pitch ratio was changed and there was exist an optimum value of pitch ratio. Thermal-hydraulic performance was found to be maximum corresponding to relative pitch value of 8.
机译:本文介绍了由于附着于加热表面的V形穿孔堵塞引起的热传递增强的实验研究。配备有穿孔V嵌段的管道具有12,相对堵塞高度(E / H)的纵横比(W / H),攻角(α)为60°,开口面积比(β)为20 %,而相对沥青比(P / E)从4到12变化。与在类似实验条件下操作的平滑管道的泡沫数量和摩擦系数的值进行比较,与堵塞的禁区的泡沫数和摩擦系数的值相同。 。发现当节距比改变时,对尿素数比和摩擦因子比具有显着影响,并且存在距离比率的最佳值。发现热液压性能最大值对应于8的相对节距值8。