首页> 外文会议>World Non-Grid-Connected Wind Power and Energy Conference >12-Pulse Auto-Transformer Rectifier with Harmonic Current Injection for Non-Grid-Connected Wind Power Applications
【24h】

12-Pulse Auto-Transformer Rectifier with Harmonic Current Injection for Non-Grid-Connected Wind Power Applications

机译:12脉冲自动变压器整流器,具有谐波电流喷射,用于非网格连接的风电应用

获取原文

摘要

Harmonics in input currents caused by three-phase rectifiers are harmful to wind turbines generators, and multi-pulse rectifiers can be used to reduce the harmonics. Multi-pulse diode rectifiers are of the property that the total harmonic distortion (THD) of input currents and the ripples of output voltage are getting lower with growing pulses, while more complex connected transformer and more diode bridges are needed. A method that connecting a resistor or power factor correction (PFC) converter to the added windings of inter-phase transformers (IPTs) of 12-pulse rectifier, injects a current to the rectifier, so as to reduce the THD of input currents. Theoretical investigation of the method is presented, and the results of simulation and experiment verify the analysis.
机译:由三相整流器引起的输入电流的谐波对风力涡轮机发生器有害,并且可以使用多脉冲整流器来减少谐波。多脉冲二极管整流器具有输入电流的总谐波失真(THD)和输出电压纹波的特性与生长脉冲越来越低,而需要更复杂连接的变压器和更多的二极管桥。一种方法,即将电阻器或功率因数校正(PFC)转换器连接到12脉冲整流器的相互相互变压器(IPTS)的附加绕组,将电流注入整流器,从而减小输入电流的THD。提出了对方法的理论研究,仿真和实验结果验证了分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号